![ultraedit script ultraedit script](https://www.ultraedit.com/assets/images/ue_screen_feature_highlights.png)
- #ULTRAEDIT SCRIPT INSTALL#
- #ULTRAEDIT SCRIPT SOFTWARE#
- #ULTRAEDIT SCRIPT CODE#
- #ULTRAEDIT SCRIPT FREE#
#ULTRAEDIT SCRIPT CODE#
Also the code folding and content assistants are based on the wordfiles inputs. Therefore highlighting literally every programming language is possible. The editor supports any UltraEdit wordfile configuration. The editor does not require UltraEdit to work. Internally it is based on the great IDM UltraEdit and the concept of UltraEdit wordfiles for syntax highlighting, trying to adopt UltraEdit's philosophy for the Eclipse workbench.
#ULTRAEDIT SCRIPT FREE#
The Wordfile Editor is a free and powerful text editor for Eclipse. Beside an elaborate syntax highlighting the editor supports additional features, such as code folding and content assistants. It is the ideal text, XML, HTML, PHP, Java, Javascript, Perl, and programmer's editor. Debugging through the script code may help to isolate the cause of the behavior in this case.The Wordfile Editor is a stand-alone, ersatile and easy to use Eclipse editor for all text based programming languages. If the issue doesn't occur with a sample project, then the setup in question is likely the issue. To determine if the installation is doing something that causes it to not work when running in the SYSTEM account, a sample project needs to be created to determine if the behavior still exists. This assumes the data in the ISS is valid for the installation and does not change if the setup is run under different user environments. The other possibility is this setup is authored to do something that does not work while running under the SYSTEM account.įor the ISS file, the path passed should be using C:\Windows\System32 as the setup.exe is 32-bit, so it will automatically be redirected to the 32-bit System32 (SysWOW64) folder. One, the path to the ISS file is invalid or inaccessible from the installation, causing the -3 result code (or it doesn't contain valid data for the installation it is passed to). There are a couple of basic possibilities. It is difficult to determine what the cause of this behavior is without knowing how the setup was authored.
#ULTRAEDIT SCRIPT INSTALL#
The error is reproduced: again only from command run as SYSTEM the install fail with error above. I have checked the extracted command line used for installation in cmd.exe window, launched from my adm* account and from system account (I started it using "psexec -i -s cmd.exe" command). In my case file is correct and, as I previouslr written, install script reads it without problem when launched from administrative account, but not from SYSTEM account (used by SCCM).
#ULTRAEDIT SCRIPT SOFTWARE#
The script installs the software fine when running from my administrative account however when I run it from SCCM client it will fail, dropping in setup.log in source directory:Īs I already figured out in the forum it is relatively common error and possibly related to problem reading *.iss file. I have developed a script to install IDM UltraEdit v17 powershell is used for this. I script for MS SCCM software distribution. Hi, I am one of the scripters in my company.